BQVQC - SUPP DATA
- MSDS: BQVQC
- Manufacturer: WEKSLER INSTRUMENTS CORP
- Product Name: SUPP DATA
- National Stock Number: 6685-01-359-1137
Product Identification
Product ID:SUPP DATA
MSDS Date:08/01/1985
FSC:6685
NIIN:01-359-1137
MSDS Number: BQVQC
Responsible Party
FREEPORT, NY 11520-0808
US
Emergency Phone: 516-623-0100
Info Phone: 516-623-0100
Cage: 64467
Contractor
Telephone: 516-623-0100
Cage: 64467
Ingredients
NITROGEN
CAS: 7727-37-9
RTECS: QW9700000
Fraction By Weight: 100%
ACGIH TLV: SIMPLE ASPHYXIANT
THEN MOVE CNTNRS AWAY FROM FIRE AREA IF
RTECS: 9999999ZZ
CONTENTS WHEN THEY ARE EXPOSED TO ELEVATED
RTECS: 9999999ZZ
TREATMENT SHLD BE DIRECTED AT THE CONTROL OF
RTECS: 9999999ZZ
PERMITTING RE-ENTRY OF PERSONNEL.
RTECS: 9999999ZZ
BEFORE YOU PRDCE MIXT. CONSULT INDUS HYG./OTHER
RTECS: 9999999ZZ
OF END PROD. REMEMBER, GASES & LIQS HAVE PROPERTIES
RTECS: 9999999ZZ
UNDERSTAND ALL LBLS & OTHER INSTRUCTIONS SUPPLIED
RTECS: 9999999ZZ
COMPRESSED GAS CYLS, IT IS RECOM THAT COPY OF
RTECS: 9999999ZZ
OBTAINED FROM COMPRESSED GAS ASSOC, INC, 1235
RTECS: 9999999ZZ
PRESSURIZED SYS. IF THERE IS LEAK, CLOSE CYL VALVE,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:"THIS TEMPERATURE INDICATOR CONTAINS
MINUTE AMOUNTS OF NITROGEN. HEALTH HAZARDS ARE BASED ON THE
HAZARDOUS COMPONENT IN THE TEMPERATURE INDICATOR (NITROGEN)". .
ACUTE:INGEST:THIS PRODUCT IS A GA S AT NORMAL TEMPERATURE &
PRESSURE. SKIN:ABSORPTION - NO EVIDENCE OF ADVERSE EFFECTS FROM
AVAILABLE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INFORMATION. CONTACT - LIQUID MAY
CAUSE FROSTBITE. INHAL:ASPHYXIANT. MODERATE CONCENTRATIONS MAY
CAUSE HEADACHE, DROWSINESS, DIZZINESS, EXCITATION, EXCESS
SALIVATION, VOMITING & UNCONSCIOUSNE SS. LACK OF OXYGEN CAN CAUSE
DEATH. EYE:NO HARMFUL EFFECT EXPECTED FROM VAPOR. CHRONIC:NO
EVIDENCE OF ADVERSE EFFECTS.
Medical Cond Aggravated by Exposure:THE TOXICOLOGY & PHYSICAL &
CHEMICAL PROPERTIES OF MATERIAL DO NOT SUGGEST THAT OVEREXPOSURE IS
LIKELY TO AGGRAVATE EXISTING MEDICAL CONDITIONS.
First Aid
First Aid:INGEST:CALL MD IMMED . SKIN:IMMED WARM FROSTBITE AREA W/WARM
WATER (NOT >105F). IN CASE OF MASSIVE EXPOS, REMOVE CLTHG WHILE
SHOWERING W/WARM WATER. CALL MD. INHAL:REMOVE TO FRESH AIR. GIVE
ARTF RESP IF NOT BRTHG. GIVE OXYGEN IF BRTHG IS DFCLT. CALL MD.
EYE:IMMED FLUSH THORO W/WATER FOR @ LST 15 MINS. SEE MD, PREF
OPHTHALMOLOGIST, IMMED. NOTES TO MD:THERE IS NO SPECIFIC ANTIDOTE.
(ING 4)
Fire Fighting
Extinguishing Media:NITROGEN CANNOT CATCH FIRE. USE MEDIA APPROPRIATE
FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. EVACUATE ALL PERS FROM DANGER AREA. IMMED DELUGE CNTNRS W/WATER
SPRAY FROM MAX DIST UNTIL COOL, (ING 2)
Unusual Fire/Explosion Hazard:GAS CANNOT CATCH FIRE. CNTNR MAY RUPTURE
DUE TO HEAT OF FIRE. NO PART OF CNTNR SHLD BE SUBJECTED TO TEMP
>52C(125F). MOST CNTNRS ARE DESIGNED TO VENT (ING 3)
Accidental Release
Spill Release Procedures:EVACUATE ALL PERS FROM DANGER AREA. USE
NIOSH/MSHA APPRVD SCBA WHERE NEEDED. SHUT OFF LEAK IF W/OUT RISK.
VENT AREA OF LEAK/MOVE LEAKING CNTNR TO WELL-VENTED AREA. TEST
AREA, ESP CONFINED AREAS, FOR S UFFICIENT OXYGEN CONTENT PRIOR TO
(ING 5)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:HIGH PRESS GAS. USE PIPING ADEQ
DESIGNED TO W/STAND PRESS TO BE ENCOUNTERED. CAN CAUSE RAPID
SUFFOCTION DUE TO OXYGEN DEFICIENCY.
Other Precautions:STORE & USE W/ADEQ VENT. CLOSE VALVE WHEN NOT IN USE
& WHEN EMPTY. WHEN 2/MORE GASES, OR LIQUIFIED GASES ARE MIXED,
THEIR HAZ PROPERTIES MAY COMBINE TO CREATE ADDNL, UNEXPECTED HAZS.
OBTAIN & EVALUATE SAFETY INFO FOR EACH COMPONENT (ING 6)
Exposure Controls
Respiratory Protection:SELECT I/A/W OSHA 29 CFR 1910.134. NIOSH/MSHA
APPROVED RESPIRATORS SHALL BE ACCEPTABLE.
Ventilation:LOCAL EXHAUST PREFERRED. MECHANICAL (GENERAL) ACCEPTABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER .
METATARSAL SHOES FOR CYL HNDLG. SELECT I/A/W OSHA 29 CFR 1910.132 &
1910.133.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO & ITEM NAME:"NSN & LOGISTICAL DATA HAS BEEN
ASSIGNED AS TEMPERATURE INDICATOR. SAFETY & HEALTH INFORMATION IS
BASED ON THE HAZARDOUS COMPONENT OF THE INDICATOR WHICH IS NITROG
EN". . DISTRIBUTOR/VENDOR FOR NITROGEN - UNION CARBIDE
(1-800-822-4357). .
Chemical Properties
HCC:G3
Boiling Pt:B.P. Text:-320F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Vapor Pres:GAS @ 20C
Vapor Density:0.967
Spec Gravity:GAS (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS AT NORMAL TEMPERATURE &
PRESSURE.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
UNDER CERTAIN CNDTNS, NITROGEN CAN REACT VIOLENTLY W/LITHIUM,
NEODYMIUM, TITANIUM, OZONE.
Stability Condition to Avoid:SEE HANDLING/STORAGE PRECAUTIONS & OTHER
PRECAUTIONS SECTIONS.
Hazardous Decomposition Products:NONE
Disposal
Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE. DISCARD ANY
PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR LINER IN AN
ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE W/FEDERAL,
STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.